| 1/2〞Aluminum RF coaxial cable |  
|  |  
| 
| Type                                     Type No. |  
| Standard cable                       HCAALY-50-12 Fire-retardant cable                HCAALYZ-50-12
 |  
| Construction |  
| Inner conductor
 | Material | CCA |  
| Diameter(mm) | 4.8±0.05 |  
| Insulation | Material | Foamed PE |  
| Diameter(mm) | 12.10±0.20 |  
| Outer conductor
 | Material | Annular corrugated
 Aluminum tube
 |  
| Diameter(mm) | 13.9±0.20 |  
| Jacket | Material | LLDPE or fire-retardant PE |  
| Min.thickness(mm) | >0.8 |  
| Diameter(mm) | 27.70±0.30 |  
| Mechnical Characteristics |  
| Bending radius(mm) | Single bend | 70 |  
| Repeated bend | 125 |  
| Tensile strength(N) | 1130 |  
| Cable weight(kg/km) | 2.0 |  
| Recommended temperature(℃) | Storage | -70~+85 |  
| Installation | -40~+60 |  
| Operating | -55~+85 |  |  
| Products meet the RoHS requirement, and according to the requirements of RoHS, you can see the RoHS mark on the outside package. |  | 
| 
| Electrical Characteristics |  
| Inner conductor DC resistance(Ω/km) | 1.48 |  
| Outer conductor DC resistance(Ω/km) | 3.00 |  
| Characteristic impedance(Ω) | 50±1 |  
| Capacitance(p F/m) | 75 |  
| Velocity(%) | 88 |  
| Dielectric strength(KV) | 6.0 |  
| Insulation resistance(MΩ/km) | >1×104 |  
| Peak power rating(KV) | 40 |  
| Shielding attenuation,(dB) | >>120 |  
| Cut-off frequency(GHz) | 8.8 |  
| Attenuation |  
| Frequency (MHz)
 | Attenuation (@20℃,d B/100m)
 |  
| 150 | 2.90 |  
| 450 | 5.23 |  
| 800 | 7.10 |  
| 900 | 7.57 |  
| 1000 | 8.00 |  
| 1500 | 10.00 |  
| 1800 | 11.10 |  
| 2000 | 11.77 |  
| 2200 | 12.32 |  
| 2500 | 13.30 |  
| 3000 | 14.74 |  
| VSWR |  
| 800MHz~1000MHz | 1.15 |  
| 1700MHz~2200MHz | 1.15 |  
| 5MHz~3000MHz | 1.25 |  |  